| DATA SHEET OF CABLE
FILLING COMPOUND - Grade CU 21 (NON HAZARDOUS) |
| SL No |
Characteristics |
Unit |
Parameters |
Method |
Results |
| |
|
|
HIGHLY
PASTED, HOMOGENEOUS POLYMER COMPOUND.DOES NOT OBSCURE COLOUR OF
INSULATION. |
|
|
| |
COLOUR AND |
|
VISUAL |
|
| 1 |
STRUCTURE |
--- |
& |
3.5 ASTM |
| |
|
|
ASTM – D1500 |
Does Not Obscure |
| 2 |
APPEARANCE |
|
FREE FROM CONTAMINATION OF FOREIGN MATTERS &
SEGREGATED OILS |
|
Free From foreign particles |
| |
|
--- |
VISUAL |
| 3 |
DENSITY |
gm/cc |
0.89±0.01 |
VOLUMETRIC ANALYSIS |
0.90 |
| 4 |
MELT DROP POINT |
°C |
80
minimum |
ASTM
- D566 |
93 °C |
| 5 |
KINEMATIC
VISCOSITY AT 100°C |
Cst |
20
- 25 |
ASTM
- D445 |
23 |
| 6 |
FLASH POINT (CLEVELAND OPEN CUP) |
°C |
232 minimum |
ASTM - D92 |
234 °C |
| 7 |
VOLUME
EXPANSION |
% |
8.0 maximum |
VOLUMETRIC METHOD |
Passes |
| 8 |
ABSORPTION IN MDPE/HDPE |
% |
8.0 maximum |
----- |
Below 8% |
| 9 |
CONE PENETRATION AT 25±0.5°C |
dmm |
50±10 |
ASTM - D937 |
48 dmm |
| 10 |
PERMITTIVITY AT 1MHZ& AT
20°C |
--- |
2.30 maximum |
ASTM – D924 |
2.24 |
| 11 |
VOLUME RESISTIVITY AT 500VDC& AT 100°C |
3 |
10 |
|
12 |
| ohm/cm |
1X10 minimum |
ASTM - D1169 |
2.11 x 10 |
| 12 |
HANDLING |
--- |
--- |
Physical |
Easily Removable |
| |
|
|
|
|
|
| 13 |
TOXIC & DERMATIC ACTION |
--- |
FREE FROM TOXIC
AND DERMATIC HAZARDS |
STANDARD |
Non Toxic & Non Dermatic. |
| 14 |
HAZARDOUSNESS |
--- |
--- |
STANDARD |
Non Hazardous & Non
Dangerous. |
NON-WARRANTY OF
RESULTS (Please use after tests and approval) |
| The sample unless
specified as IP is meant for Industrial Use only. Our recommendations for its
use |
| are purely based on
tests believed reliable. Since the use is beyond our control we do not
guarantee |
| the results whether
or not such use is in accordance with directions. It is also unedrstood that
the quality |
| and specifications
of the sample are typical only. |
|
|
|
|
|
|